Installation and Operation of the Caterpillar Diesel Particulate Filter (DPF) and the Diagnostic Module for Non-Road Machine Applications (Non-California Applications)

Diagnostic Module Specifications

 

Diagnostic Module Electro-Mechanical

Table 8
Diagnostic Module Electro-Mechanical
Housing Metallic enclosure, near the weatherproof seal, with sealing gland type fittings for the wire egress.
Dimensions 10 X 6 X 3.5 with a tab/flange at each end for surface mounting.
Wiring Connections Via the weather pack or Deutsche and mini Type-K connectors on three separate pigtails. No user serviceable connectors are inside the enclosure.
Wiring Egress Sealing gland type fittings. Sealed serial connection on electronics module cover.
Pressure Connection Via an 18 NPT fitting directly onto the integral pressure transducer.
Ambient Operating Temperature −30° C to 85° C (−22° F to 185° F)

 

Diagnostic Module Electrical

Table 9
Diagnostic Module Electrical
Supply Voltage Input range 12 vdc to 24 vdc
Supply Current 50mA average current, 150mA max current, including all sensor excitation.
Cold Junction Compensation (CJC) Integral via the on board sensor at the thermocouple connection point. CJC accuracy to add less than
±1.5° C (±35° F) error over specified Diagnostic Module ambient operating range (typical will be less than
±0.6° C (±33.0° F)
ADC Resolution 10 bit unipolar, will result in approximately
2° C (36° F) resolution for temperature and 0.1 in Hg for pressure.
ADC Accuracy Max (over temp): ±4 bits%.
System Accuracy Temperature Error Max:
±5° C (±41° F) (typical
±2° C (±36° F)). Pressure Error: ±1.5% typical, 3% max.
Sample Capacity The exhaust monitor can store approximately 260,000 records in internal memory. Dynamic allocation of memory space is implemented to allow for asynchronous event storage (for example: alarms).
RTC Integral real-time clock with 10 year life expectancy lithium cell backup. Ambient temperature (
25° C (77° F)) accuracy of ±30 seconds/month.
Glitch Recovery The Diagnostic Module microprocessor is equipped with a hardware watch dog timer to restore normal operation in the event of a system upset.
Alarm Outputs Two outputs. Alarm 1 is an open collector transistor output. Alarm 2 is a relay output. The normally closed contacts of this relay are used to add a level of fail-safe integrity to the system. The relay is utilized in the event of a system power failure. The relay will short Terminal strip TS2, Position 4 to ground upon alarm condition. The relay will also short Terminal strip TS2, Position 4 to ground in the event of a power failure of the Diagnostic Module.
Serial Data Port Multiwire serial interface for connection to a PC. A fixed baud rate of 115K/baud is supported.
Software Restart Upon interruption and reapplication of power, the exhaust monitor will start normal operation including data logging and alarm functions.

 

Pressure Transducer

Table 10
Pressure Transducer
Housing Cylindrical machined 316 SS housing. Unit will be contained within the Diagnostic Module.
Diaphragm 316L
Operating Temperature Range −40° C to 125° C (−40° F to 257° F)
Shock 100 G for 11mSec.
Vibration 10 G at 20 to 2000 Hz.
Lifetime 1 million cycles.
Temperature Compensated Range −10° C to 85° C (14° F to 185° F)
FS Range 0 to 20 in Hg (0 to 10 PSIG) suggested.
140 kPa (20 psi) Proof/Max. As deployed in Diagnostic Module, the usable pressure range is 0 to 20 in hg.
Accuracy Type: ±1.5%FS over temp. Max: ±3%FS.
Pressure Connection Via an 18 NPT fitting directly onto the integral pressure transducer.
Supply Power Power will be supplied through the Diagnostic Module. The power supply will be pre-regulated and surge protected.

 

Temperature Sensor

Table 11
Temperature Sensor
Type “K” Thermocouple
Package 1/8 inch diameter X 8 inch long Inconel 600 insertion probe compatible with Swagelok type compression fitting. Ungrounded thermocouple in the high temp magnesium oxide insulator with the MGO cement cap. Provided with
6.1 m (20 ft) electrically shielded Teflon leads with
0.9 m (3 ft) of spiral armor at the probe end. Lead rated
260° C (500° F) continuous. Probe tip rated
1000° C (1832° F) continuous.
Temperature Range
(Withstand)
−100° C to 1000° C (−148° F to 1832° F) continuous.
Temperature Range
(Operational)
0° C to 1000° C (32° F to 1832° F)
Sensor Accuracy Special Limits TC wire used:
±1.1° C (±34° F) or ±0.4%rdg whichever is greater over range
0° C to 1000° C (32° F to 1832° F).