C7 Industrial Engines Disassembly and Assembly – Water Temperature Regulator – Remove and Install

Removal Procedure
Start By:

Remove the water temperature regulator housing. Refer to Disassembly and Assembly, “Water Temperature Regulator Housing – Remove and Install”.

  1. Remove bolts (1) and the washers from outlet pipe (2) .

 

  1. Remove outlet pipe (2) and gasket (3) .

 

  1. Remove water temperature regulators (4) from water temperature regulator housing (5) .

Installation Procedure

  1. Clean the mating surfaces of the water temperature regulator housings.

  1. Position water temperature regulators (4) into water temperature regulator housing (5) .

 

  1. Install a new gasket (3) and outlet pipe (2) .

 

  1. Install bolts (1) and the washers. Tightened bolts (1) to a torque of 28 ± 7 N·m (21 ± 5 lb ft).

End By: Install the water temperature regulator housing. Refer to Disassembly and Assembly, “Water Temperature Regulator Housing – Remove and Install”.