Conditions Which Generate This Code:
The inlet air temperature has exceeded the trip level.
| Trip Level | Set Point (sec) | Reset Level | Reset Time |
| 75 °C (167 °F) | 4 sec | 73 °C (163 °F) | 4 sec |
The Electronic Control Module (ECM) will not act until the engine speed is greater than 0 rpm for three minutes.
System Response:
The warning lamp will turn ON while the “Warning” is active. The ECM will log the code.
- There may be a problem with the aftercooler.
Test Step 1. Check for Diagnostic Codes
- Connect Caterpillar Electronic Technician (ET) to the service tool connector.
- Place the engine control in the ON mode. The engine should be off.
- Check for any active diagnostic codes or logged diagnostic codes.
Expected Result:
There should be no diagnostic codes that are present.
Results:
- OK – Proceed to Test Step 2.
- Not OK –
Repair: Repair the diagnostic codes that are present. Refer to the appropriate topic in the “Troubleshooting With a Diagnostic Code” section of this manual.Ensure that the repair eliminates the problem.
STOP
Test Step 2. Perform a Check of the Aftercooler
- Perform a check of the aftercooler. Refer to the appropriate topic in Testing and Adjusting for possible causes.
Expected Result:
There are no problems with the aftercooler.
Results:
- OK – There may be an intermittent problem.
Repair: Monitor the operation of the engine.Repair the problem.Ensure that the repair eliminates the problem.
STOP
- Not OK –
Repair: Repair the problem.Ensure that the repair eliminates the problem.
STOP