C-10, C-12, C-15 and C-16 Industrial Engines – CID 1835 FMI 04 Auxiliary Pressure Sensor short to gr

Conditions Which Generate This Code:

The Electronic Control Module (ECM) detects a signal voltage from the auxiliary pressure sensor that is below normal.

System Response:

The ECM logs the diagnostic code. The value of the auxiliary pressure is set to a default value.

  • There are no performance effects.

Test Step 1. Perform the following diagnostic procedure: Engine Pressure Sensor Open or Short Circuit – Test

Results:

  • OK – STOP