C-10, C-12, C-15 and C-16 Industrial Engines – CID 0274 FMI 03 Atmospheric Pressure open/short to +b

Conditions Which Generate This Code:

The signal voltage from the atmospheric pressure sensor is above 4.8 VDC for at least eight seconds.

System Response:

The Electronic Control Module (ECM) will log the diagnostic code. The ECM flags atmospheric pressure as invalid data and a default value of 100 kPa (15 psi) is used.

Low power

Test Step 1. Perform the following diagnostic procedure: Engine Pressure Sensor Open or Short Circuit – Test

Results:

  • OK – STOP