C-10, C-12, C-15 and C-16 Industrial Engines – CID 0263 FMI 04 Digital Sensor Supply short to ground

Conditions Which Generate This Code:

The Electronic Control Module (ECM) detects supply voltage that is below normal.

System Response:

The ECM will log the diagnostic code. The ECM flags all digital sensors as invalid data and all digital sensors are set to the respective default values.

  • The engine may experience low power.

Test Step 1. Perform the following diagnostic procedure: Digital Sensor Supply Circuit – Test

Results:

  • OK – STOP