C-10, C-12, C-15 and C-16 Industrial Engines – CID 0262 FMI 04 5 Volt Sensor DC Power Supply short t

Conditions Which Generate This Code:

The 5 volt sensor supply voltage drops below normal.

System Response:

The Electronic Control Module (ECM) logs the diagnostic code. The ECM flags all 5 volt sensors as invalid data and the respective default values are used.

  • The engine may experience low power.

Test Step 1. Perform the following diagnostic procedure: 5 Volt Engine Pressure Sensor Supply Circuit – Test

Results:

  • OK – STOP