C-10, C-12, C-15 and C-16 Industrial Engines – CID 0041 FMI 04 8 Volt DC Supply short to ground

Conditions Which Generate This Code:

The voltage level of the 8 volt supply is below normal.

System Response:

The Electronic Control Module (ECM) logs the diagnostic code. The ECM flags all digital sensors as invalid data and all digital sensors are set to the respective default values.

  • The engine may experience low power.

Test Step 1. Perform the following diagnostic procedure: Digital Sensor Supply Circuit – Test

Results:

  • OK – STOP