Installation Procedure
Illustration 1 g00644655
Use Tooling (A) in order to install the injection actuation pressure control valve on the unit injector hydraulic pump. Tighten the injection actuation pressure control valve to a torque of 50 ± 5 N·m (37 ± 4 lb ft).
Illustration 2 g00644654
Install the solenoid valve, the spacer, and nut (3) on the injection actuation pressure control valve (1). Tighten nut (3) to a torque of 5.5 ± 1.5 N·m (49 ± 13 lb in).
Reconnect harness assembly (2) to the injection actuation pressure control valve.