Air Inlet Heater Wiring Group Replacement for Certain C7 and C9 Industrial Engines

Engine:
C-9 (S/N: CLJ1-UP)
C7 (S/N: JRA1-UP; JTF1-UP; RMF1-UP)
Industrial Engine:
C9 INDUSTRIAL (S/N: JSC1-UP; MBD1-UP)

 

Introduction

The purpose of this Special Instruction is to replace the existing magnetic switch group with a more robust magnetic switch group that will withstand high vibration over longer periods of time.

 

Safety Information

New 24V 233-0081 Heater Wiring Group for C7 Engines with Serial Number Prefixes JTF and JRA

Table 1
New Parts Required for Rework
Callout Quantity Part Number Description
6 3 357-3513 Bolt M8 x 40 mm
7 3 267-4211 Spacer 15mm
8 1 398-0940 Magnetic Switch Gp 24V
9 1 415-7171 Cable As
10 1 397-6079 Plate
12 1 3S-2093 Cable Strap

 

Parts to be Removed from the Existing 233-0081 Heater Wiring Group

Table 2
Parts to Remove
Callout  Quantity Part Number Description
1
Retain for rework.
2 208-9277 Bolt M6 x 20mm
2 1 209-5582 Magnetic Switch Gp 24V
3 1 231-1223 Cable As
4 2 208-9283 Bolt M8 x 30mm
5 1 283-1224 Bracket As

New 233-0081 Air Inlet Heater Magnetic Switch Orientation

Wiring Group 233-0081 Rework 24V

Table 3
All Parts Required for Rework
Callout Quantity Part Number Description
1
This part retained from removal procedure.
2 208-9277 Bolt M6 x 20mm
6 3 357-3513 Bolt M8 x 40 mm
7 3 267-4211 Spacer 15mm
8 1 398-0940 Magnetic Switch Gp 24V
9 1 415-7171 Cable As
10 1 397-6079 Plate
11 2 Power Terminals:
Torque the nuts to 9 ± 1 N·m (80 ± 9 lb in)
12 1 3S-2093 Cable Strap