Conditions Which Generate This Code: Engine speed has exceeded the trip point for engine overspeed. System Response: The Electronic Control Module (ECM) will log the…
Author: sam
Table 1 Event Codes EID Description of Code 004 Engine Overspeed Shutdown 005 …
C-10, C-12, C-15 and C-16 Industrial Engines – CID 1836 FMI 08 Auxiliary Temperature Sensor signal a
Conditions Which Generate This Code: The Electronic Control Module (ECM) detects all of the following conditions: Either the duty cycle is greater than 95 percent…
C-10, C-12, C-15 and C-16 Industrial Engines – CID 1835 FMI 04 Auxiliary Pressure Sensor short to gr
Conditions Which Generate This Code: The Electronic Control Module (ECM) detects a signal voltage from the auxiliary pressure sensor that is below normal. System Response:…
Conditions Which Generate This Code: The Electronic Control Module (ECM) detects a signal voltage that is above normal. System Response: The ECM logs the diagnostic…
Conditions Which Generate This Code: The Electronic Control Module (ECM) detects all of the following conditions: The ECM has detected an open or a short…
C-10, C-12, C-15 and C-16 Industrial Engines – CID 0342 FMI 11 Secondary Engine Speed Sensor mechani
Conditions Which Generate This Code: The signal for the secondary speed/timing sensor is intermittent or lost. System Response: The Electronic Control Module (ECM) will log…
C-10, C-12, C-15 and C-16 Industrial Engines – CID 0342 FMI 02 Loss of Secondary Engine Speed signal
Conditions Which Generate This Code: The signal from the secondary engine speed/timing sensor is intermittent or lost for less than one second. System Response: The…
C-10, C-12, C-15 and C-16 Industrial Engines – CID 0320 FMI 11 Speed/Timing Sensor mechanical failur
Conditions Which Generate This Code: The signal for the primary engine speed/timing sensor is lost for more than one second. System Response: The Electronic Control…
Conditions Which Generate This Code: The signal for the primary engine speed/timing sensor is intermittent or lost for less than one second. System Response: The…