1. When engine mounted water temperature, oil pressure and/or overspeed contactors close, current flows through solenoid of shutdown relay which energizes shutoff circuit and alarm…
Author: sam
1. When engine is required to start, initiating contacts close, thus energizing initiating relay. Magnetic switch is energized through IR and AR contacts. Magnetic switch…
AUTOMATIC START-STOP SYSTEM COMPONENT LOCATION DIAGRAM This describes a typical application of the automatic start-stop system for diesel engines. NOTE: The natural gas engine automatic…
HYDRAULIC START DIAGRAM Hydraulic cranking systems operate on the principle of pressure oil turning a fluid motor to produce mechanical energy. The oil is stored…
AIR STARTING SYSTEM 1. Balanced whistle valve. 2. Oiler. 3. Air motor. The air starting system is mounted on the right side of the engine.…
OUTPUT SHAFT GOVERNOR AND HYDRAULIC SERVO MECHANISM 1. Flexible drive cable. 2. Output shaft governor. 3. Terminal lever. 4. Rocker shaft. 5. Rate adjusting screw.…
The oil supply is from the engine lubrication system. This oil is supplied to the governor oil pump which boosts it to 175 psi (12,3…
Whenever the solenoid is installed, the pinion clearance should be adjusted. The adjustment should be made with the starting motor removed. CONNECTIONS FOR CHECKING PINION…
Use a D.C. voltmeter to locate starting system components which do not function. Push the start switch button or turn the HEAT-START switch to the…
Cylinder Liner Projection 1P2394 Adapter Plate.Two 3H465 Plates.Crossbar (from 8B7548 Push-Puller).Two 5/8″-11 NC bolts, 5.5 in. (118.7 mm) long.Two 4B4281 Washers.1P5510 Liner Projection Tool Group.…