Required Tools | ||
Part Number | Part Name | Quantity |
1P-3537 | Dial Bore Gauge Group | 1 |
Illustration 1 | g00285686 |
1P-3537 Dial Bore Gauge Group |
If the main bearing caps are installed without bearings, the bore in the block for the main bearings can be checked. Tighten the nuts on the bearing caps to the torque that is given in Specifications, “Cylinder Block”. Alignment error in the bores must not be more than 0.08 mm (0.003 inch).
The 1P-3537 Dial Bore Gauge Group can be used to check the size of the bore.