3208 INDUSTRIAL ENGINE – Water Separator

Remove Water Separator


NOTICE

Element (2) is free to fall when clamp (1) is released.


1. Remove clamp (1) and element (2).

2. Disconnect line (4) from the water separator base.

3. Remove the two nuts and water separator base (3).

4. Remove three bolts (6), bracket (5) and spacers.

Install Water Separator

1. Put bracket (1) and three spacers in position. Install the three bolts. Tighten the bolts to a torque of 10 ± 2 lb.ft. (14 ± 3 N·m).

2. Put base (2) in position and install the nuts.

3. Connect line (3) to the base.

4. Put element (4) in position and install clamp (5).

NOTE: Make sure clamp (5) is tight because element (4) is free to fall.