7C5417 Switch
Switch operates when the temperature increases to … 97 to 99°C (208 to 210°F)
5N8857 Switch
Terminal A is normally open below actuation temperature.
Terminal B is common.
Terminal C is normally closed below actuation temperature.
With a temperature increase to 96.5 to 99.5°C (206 to 211°F), terminal A closes and terminal C opens.
With a temperature decrease to 91°C (196°F), terminal A opens and terminal C closes.
(1) Final torque for switch assembly … 52 ± 8 N·m (38 ± 6 lb ft)
9Y0914 Switch
Terminal A is normally open below actuation temperature.
Terminal B is common.
Terminal C is normally closed below actuation temperature.
With a temperature increase to 100 to 103°C (213 to 217°F), terminal A closes and terminal C opens.
With a temperature decrease to 94.5°C (202°F), terminal A opens and terminal C closes.
(1) Final torque for switch assembly … 52 ± 8 N·m (38 ± 6 lb ft)
8N1693 Switch For Ether Aid
Switch must open between … 35 to 41°C (95 to 106°F)
Switch must close at a minimum of … 27°C (81°F)