26SI Series Alternator – Water Temperature Switches

7C5417 Switch

Switch operates when the temperature increases to … 97 to 99°C (208 to 210°F)

5N8857 Switch

Terminal A is normally open below actuation temperature.

Terminal B is common.

Terminal C is normally closed below actuation temperature.

With a temperature increase to 96.5 to 99.5°C (206 to 211°F), terminal A closes and terminal C opens.

With a temperature decrease to 91°C (196°F), terminal A opens and terminal C closes.

(1) Final torque for switch assembly … 52 ± 8 N·m (38 ± 6 lb ft)

9Y0914 Switch

Terminal A is normally open below actuation temperature.

Terminal B is common.

Terminal C is normally closed below actuation temperature.

With a temperature increase to 100 to 103°C (213 to 217°F), terminal A closes and terminal C opens.

With a temperature decrease to 94.5°C (202°F), terminal A opens and terminal C closes.

(1) Final torque for switch assembly … 52 ± 8 N·m (38 ± 6 lb ft)

8N1693 Switch For Ether Aid

Switch must open between … 35 to 41°C (95 to 106°F)

Switch must close at a minimum of … 27°C (81°F)