Removal Procedure
1.Drain the coolant from the cooling system into a suitable container for storage or disposal.
Illustration 1 g00998971
2.Remove bolts (2) from water temperature regulator housing (1) .
3.Remove water temperature regulator housing (1). Remove the gasket from water temperature regulator housing (1) .
Installation Procedure
Illustration 2 g00998971
1.Position a new gasket and water temperature regulator housing (1) on the cylinder block.
2.Install bolts (2) .
3.Fill the cooling system with coolant to the correct level. Refer to the Operation and Maintenance Manual for the correct filling procedure.