Description:
The Torque Limit parameter defines the maximum torque output of the engine during Dedicated PTO operation. The maximum value is the Rated Torque of the engine. If the Torque Limit is Programmed to a value higher than the rated torque of the engine, the torque limit is ignored.

Available:
All electronically controlled on-highway engines covered in this handbook

Range:

Advantages:
By programming a Torque Limit the ECM can help prevent damage to engine driven PTO devices due to over-torque from the engine.

Disadvantages:
None

Recommendations:
Refer to RENR1282 for additional information.

 