Introduction When the words “use again” are in the description, the specification given can be used to determine if a part can be used again.…
Author: sam
Introduction NOTE: For Specifications with illustrations, make reference to Specifications For 3208 Industrial Engine, SENR3687. If the Specifications in SENR3687 are not the same as…
Introduction NOTE: The specifications given for “use again” and “permissible” are intended for guidance only and Caterpillar Tractor Co. hereby expressly denies and excludes any…
Electrical System Contactor Switch For Water Temperature The contactor switch for water temperature is installed in the front cover for the engine. No adjustment to…
Remove & Install Fuel Injection Nozzles Start By: a. remove valve covers Fluid Spillage Containment Care must be taken to ensure that fluids are contained…
9F3099 Switch Current consumption (draw) at 24V … 0.82 ± 0.06 A (1) Torque for large terminal nuts … 3.6 ± 0.4 N·m (32 ±…
Terminal No. 2 is normally open. Terminal No. 3 is normally closed. When installing, tighten switch to a maximum torque of … 40 N·m (30…
7C5417 Switch Switch operates when the temperature increases to … 97 to 99°C (208 to 210°F) 5N8857 Switch Terminal A is normally open below actuation…
Remove Electric Starting Motor 1. Disconnect the battery cables. 2. Disconnect and put identification marks on the wiring for the electric starting motor. 3. Disconnect…
8C3643 (12V), 6V3969 (12V) Rotation as viewed from drive end … Clockwise No load conditions at 25°C (77°F): Speed … 6900 ± 1800 rpm Current…