(1) Depth of bore in block for liner … .401 ± .001 in.(10.19 ± 0.03 mm) Height of liner over block (under installation pressure) ……
Author: sam
Temperature that makes the regulator start to open … 175° F(80° C) Approximate temperature when completely open … 195° F(90° C)
4L7615 ILLUSTRATED 6L5851 Regulator: Temperature that makes the regulator start to open … 172 to 177° F(78 to 80° C) Approximate temperature when completely open…
(1) 8M3182 Spring for oil cooler bypass valve: Length under test force … 2.5 in.(63.5 mm) Test force … 8.92 lb.(4.05 kg) Free length after…
(1) Torque for the bolt … 20 ± 5 lb.ft.(2.8 ± 0.7 mkg) (2) 8M3182 Spring for oil filter and oil cooler bypass valves: Length…
(1) Diameter of the drive shaft (new) … .8747 ± .0002 in.(22.217 ± 0.005 mm) Maximum permissible clearance between shaft and bearing (worn) … .005…
(1) Diameter of the drive shaft (new) … .8747 ± .0002 in.(22.217 ± 0.005 mm) Maximum permissible clearance between shaft and bearing (worn) … .005…
(1) Torque for nuts holding the manifold to the cylinder head: a. Put 9M3710 Anti-Seize Compound on threads of stud. b. Hand tighten nuts to…
(1) Install impeller as follows: a. Get temperature of impeller to … 350° F(177° C) (for ten minutes) b. Install impeller on shaft. c. Tighten…
(1) Install impeller as follows: a. Get temperature of impeller to … 350° F(177° C) (for ten minutes) b. Install impeller on shaft. c. Tighten…