Removal Procedure
- Disconnect harness assembly (1) from turbocharger outlet pressure sensor (2) .
- Remove turbocharger outlet pressure sensor (2) and the O-ring seal.
Installation Procedure
Note: Check the O-ring seal for wear or damage. If necessary, replace the O-ring seal.
- Install the O-ring seal on turbocharger outlet pressure sensor (2) .
- Install turbocharger outlet pressure sensor (2). Tighten turbocharger outlet pressure sensor (2) to a torque of 10 ± 2 N·m (88 ± 18 lb in).
- Connect harness assembly (1) to turbocharger outlet pressure sensor (2) .