Rating … 12V Pressure range … 0 to 120 psi(0 to 830 kPa) Calibration test at 14V (30° mounting): 0 psi (0 kPa) … 240…
Category: 3208
Remove & Install Oil Level Gauge 1. Remove nut and washer (1). 2. Disconnect nut fitting (3). 3. Remove oil level gauge (2) from oil…
(1) Guide assembly. Assemble lower part of guide assembly (1) so that Point A is even with bottom surface of block within ± 0.8 mm…
(1) Guide assembly. Assemble lower part of guide assembly (1) so that Point A is even with bottom surface of block within ± .03 in.…
Remove Water Separator NOTICE Element (2) is free to fall when clamp (1) is released. 1. Remove clamp (1) and element (2). 2. Disconnect line…
Remove Fuel Injection Nozzles start by: a) remove rocker shafts 1. Thoroughly clean the area around each fuel line connection. Disconnect fuel injection line (1)…
Remove Fuel Injection Lines 1. Disconnect lines (1) and (2). 2. Remove bolt (3) from the bracket. 3. Loosen nuts (4) at the cylinder head…
122-9007 (1) Torque for valve lift locknut … 4 to 5 N·m (35 to 45 lb in) (2) Torque for pressure screw locknut … 8.0…
Bench test nozzles using clean SAE J967 Calibration Oil (Kent-Moore Corp. J-26400 or Viscor Calibration Fluid 1487C-SAE J-967C) at a temperature of … 65 to…
Remove Fuel Injection Pumps Start By: a. remove fuel injection lines b. remove shutoff housing, check valve and bypass valve Fluid Spillage Containment Care must…